Productos
HPMETER1™
Energy Project Solutions HPmeter1™ (High Pressure) Single Chamber Orifice fittings are manufactured to meet stringent industry standards and safety guidelines and are designed to meet the end users expectations.
All our products are designed using DFM (Design For Manufacture) and DFA (Design For Assembly) techniques. This has resulted in products differentiated by their simplicity, reduced level of complex parts, and consequently provide the end user with a product that is remarkably simple to use, and is virtually maintenance free.
The “HPmeter1” product range has been rationalised to the extent that we can offer significantly reduced lead times on this range.
6” 2500# HPmeter1™ Single Chamber
Benefits
- High Accuracy, precision machined orifice fitting.
- Minimal maintenance required.
- Plate0 ® Quick release plate system that is impossible to install backwards
- Use of modern seals and simplest designs
- Field-repairable
Options
- Exotic Materials for demanding service – Duplex, Inconel.
- High Pressure solutions
- Wide Temperature ranges.
- Stainless Internals as standard
- Meter Runs and accessories
- Bespoke design service available
Standard Materials of Construction
- Body Casting – ASTM A487 4D
- Internal components – Stainless Steel 316
- Seals – Selected per application
- External Bolting – ASTM A194 L7 (HDG)
- Other materials are available upon request
Orifice Plates
The HPmeter1™ , meter1 and meter2 orifice fittings use industry standard orifice plate thicknesses as per the guidelines set out within ISO 5167 and API 14.3.
Body Configurations
Flange x Flange, Flange x Weld or Weld x Weld FF (Flat Face), RF (Raised Face), RTJ (Ring Type Joint)
Flanges available in the following formats;
- ANSI 16.5, 16.47
- Techlok & SPO
- Graylok
- API 6A
Design Codes
- ASME B31.8 Gas Transmission and Distribution Piping
- NACE MR-01-75
- ASME B31.1 Power Piping
- ASME B31.3 Liquid Petroleum
- PED 97/23/EC – Pressure Equipment Directive
Measurement Standards
ISO 5167
API MPMS 14.3.2 (AGA Report No.3)
Maximising the HPmeter1™
To ensure absolute metering accuracy, it is recommended that meter tubes are purchased and manufactured to complement the orifice fitting. This ensures concentricity between the pipe and the fitting, and eliminates uncertainties associated with misalignment. EPS can supply the following items for a complete metering solution;
- Orifice fitting with Meter Tube including straightening vane/profiler
- DP transmitters and Process Transmitters
- Flow Computer and Enclosure
METER2®
Energy Project Solutions meter2 TM Dual Chamber Orifice fittings are manufactured to meet stringent industry standards and safety guidelines and are designed to meet the end users expectations.
All our products are designed using DFM (Design For Manufacture) and DFA (Design For Assembly) techniques. This has resulted in products differentiated by their simplicity, reduced level of complex parts, and consequently provide the end user with a product that is remarkably simple to use, and is virtually maintenance free.
The “meter2” product range has been rationalised to the extent that we can offer significantly reduced lead times on this range.
8” 900 meter2 TM Dual Chamber orifice
Benefits
- High Accuracy, precision machined orifice fitting.
- Minimal maintenance required.
- Plate0 ® – Quick release plate system that is impossible to install backwards
- Modular design – a meter1 TM can be upgraded to a meter2 TM whilst installed in the pipeline.
- Use of modern seals and simplest designs
- Field-repairable
Options
- Exotic Materials for demanding service – Duplex, Inconel.
- High Pressure solutions (10,000PSI).
- Wide Temperature ranges.
- Stainless Internals as standard
- Meter Runs and accessories
- Bespoke design service available
- ‘Double Isolation’ option
The meter2 TM dual chamber orifice fitting can be installed into horizontal or vertical lines. Each product has been fully FEA (Finite Element Analysis) tested at design stage ensuring maximum safety to the user and the system. Upon product assembly, each product is fully pressure tested tosatisfy industrysafety,European pressure guidelines and product expectations.
Design Codes
- ASME B31.8 Gas Transmission and Distribution Piping
- NACE MR-01-75
- ASME B31.1 Power Piping
- ASME B31.3 Liquid Petroleum Transportation Piping Systems
- PED 97/23/EC – Pressure Equipment Directive
- HSG253 – The safe isolation of plant and equipment
Measurement Standards
- ISO 5167
- API MPMS 14.3.2 (AGA Report No.3)
Body Configurations
Flange x Flange, Flange x Weld or Weld x Weld FF (Flat Face), RF (Raised Face), RTJ (Ring Type Joint)
Flanges available in the following formats;
• ANSI 16.5, 16.47
• Techlok & SPO
• Graylok
• API 6A
Maximising the meter2 ®
To ensure absolute metering accuracy, it is recommended that meter tubes are purchased and manufactured to complement the orifice fitting. This ensures concentricity between the pipe and the fitting, and eliminates uncertainties associated with misalignment. EPS can supply the following items for a complete metering solution;
- Orifice fitting with Meter Tube including straightening vane/profiler
- DP transmitters and Process Transmitters
- Flow Computer and Enclosure
Standard Materials of Construction
Body Casting – ASTM A352 LCC
- Pressure Caps/Covers – ASTM A516 Gr.70
- Internal components – Stainless Steel 316
- Seals – Selected per application
- External Bolting – ASTM A194 L7 (HDG)
- Other materials are available upon request
Orifice Plates
The meter1 and meter2 orifice fittings use industry standard orifice plate thicknesses as per the guidelines set out within ISO 5167 and API 14.3.
METER2DI®
The meter2di “Dual Chamber Orifice fitting with Double Isolation” is a proven system for safely and quickly inspecting and changing orifice plates in line with strict industry guidelines.
The meter2di solution is compliant with HSG253 publication ‘The safe isolation of plant and equipment’ and is classed as “Category II Proved Isolation”. All valve and internal chambers shafts can be ‘locked’ providing a physical and visible means of control, and is in compliance with many of the operators ‘isolation philosophy’s’.
Each product has been fully FEA (Finite Element Analysis) tested at design stage ensuring maximum safety to the user and the system. The meter2di has undergone a series of rigorous cycling tests ensuring the repeatability of the seals and equipment. Upon product assembly, each product is fully pressure tested to satisfy industry safety, European pressure guidelines and product expectations.
8” 900 meter2di Dual Chamber with Double Isolation
Benefits
- Double isolation with visible proofing mechanism – HP and LP pressure gauges.
- All valve and internal chamber seals can be locked into position.
- Safe change out of plates.
- Increased turn down capability.
- Reduced operating costs – Uninterrupted gas flow whilst plates are safely inspected.
- As there are no calibration requirements on orifice plates, the solution is an economic option against ultrasonic and cone meters.
- Flexibility – Maintenance can be performed at any time and not scheduled into the installations annual shut down period.
- High pressure solution for 2500# ANSI meters. Duplex manifold rated to 10,000PSI.
- Patent Pending.
Design Codes
- ASME B31.8 Gas Transmission and Distribution Piping
- NACE MR-01-75
- ASME B31.1 Power Piping
- ASME B31.3 Liquid Petroleum Transportation
Piping Systems - PED 97/23/EC – Pressure Equipment Directive
- HSG253 – The safe isolation of plant and
equipment
Measurement Standards
- ISO 5167
- API MPMS 14.3.2 (AGA Report No.3)
Body Configurations
Flange x Flange, Flange x Weld or Weld x Weld FF (Flat Face), RF (Raised Face), RTJ (Ring Type Joint)
Flanges available in the following formats;
- ANSI 16.5, 16.47
- Techlok & SPO
- Graylok
- API 6A
Maximising the meter2di ®
To ensure absolute metering accuracy, it is recommended that meter tubes are purchased and manufactured to complement the orifice fitting. This ensures concentricity between the pipe and the fitting, and eliminates uncertainties associated with misalignment. EPS can supply the following items for a complete metering solution;
- Orifice fitting with Meter Tube including straightening vane/profiler
- DP transmitters and Process Transmitters
- Flow Computer and Enclosure
Standard Materials of Construction
- Body Casting – ASTM A352 LCC
- Pressure Caps/Covers – ASTM A516 Gr.70
- Internal components – Stainless Steel 316
- Seals – Selected per application
- External Bolting – ASTM A194 L7 (HDG)
- Other materials are available upon request
Orifice Plates
The meter1 and meter2 orifice fittings use industry standard orifice plate thicknesses as per the guidelines set out within ISO 5167 and API 14.3.
METER RUNS
EPS meter runs form an integral part of the measuring system, and are used both up and downstream of the EPS meter. EPS meter runs are manufactured to meet stringent industry measurement and piping standards and safety’ guidelines. Designed to meet the end users expectations, they are designed to ensure that the meter run can be installed with total confidence.
Tapping points for instrumentation can be provided within the design for both upstream and downstream connections points, e.g. thermo-wells, densitometers. All of the EPS DP meters can be included into a meter run as well as flow conditioners/straighteners, DP transmitters, single point data transmitters, Diagnostics for CBM (Condition Based Monitoring) and flow compUters can be included within the solution to make a more complete ’Measurement System’.
EPS meter runs are designed to suit and comply with the specific customer requirements and needs. As with the DP meters EPS can offer, our meter runs can be supplied in all materials from carbon steels through to Super Duplex. Pipe end configurations are available as either welded or flanged in accordance with a variety of industry recognised flange standards or in compliance with the client specific flange requirements.
EPS Meter runs are manufactured in strict accordance with industry standards and are supplied with detailed measurement verification, materials certification and where applicable in compliance with PED 97/23/EC (Pressure Equipment Directive) and other client/region specific codes.
It is the combined manufacturing and dimensional accuracy of the meter and that of the meter run piping that provides the ’system accuracy’.
It is for that reason why EPS recommend purchasing a complete measurement system from EPS, comprising of an EPS DP meter and meter run, to optimise the metering accuracy.
All EPS meters can be supplied complete with a meter run, to further optimise the metering accuracy.
Meter Run – End Configurations
Flange x Flange, Flange x Weld or Weld x Weld
FF (Flat Face), RF (Raised Face), RTJ (Ring Type Joint)
Flanges available in the following formats;
- ANSl B16.5, 816.47
- Techlok & SPO
- Graylok
- APl 6A
- Client specifications
Design Codes
- ASME 831.8 Gas Transmission and Distribution Piping
- NACE MR—01-75
- ASME 831.1 Power Piping
- ASME 831.3 Process Piping
- PED 97/23/EC — Pressure Equipment Directive
Benefits
- High Accuracy, precision machined meter run.
- Minimal maintenance required.
- Dowelled alignment for flanged options.
- Radiography, surface finish and concentricity verified to meet customer needs.
- Available in a broad range of materials
Pressure ratings from ANSI 150-2500# and also up to 10,000 PSI - Can be supplied to cladding specification if required.
Options
- Standard carbon steels through to exotic Materials for demanding service — Duplex, Inconel.
- Options to purchase meter run sections without meters
- Option to purchase measurement system including meter run and accessories i.e. flow conditioners, transmitters, flow computers, enclosures.
- Bespoke design service available
For more information please contact EPS@LEADING.ES
Measurement Standards
- ISO 5167
- API MPMS 14.3.2 (AGA Report No.3)
VENTURI METERS
EPS Venturi Meters are manufactured to meet stringent industry standards and safety guidelines and are designed to meet the end users expectations.
Venturi meters are used on applications where a low permanent pressure loss is desired. This type of ‘Differential Pressure Meter’ can be used on a wide variety of flow mediums and include slurry, heavy oil, sludge, liquid, vapour, gas and high pressure steam.
EPS Venturi meters are produced using 3 main manufacturing methods, selected to best suit the material and size of the meter. These are detailed in ISO 5167-4:2003 and permit the use of specific Beta ranges.
12” 600 Venturi Meter
Body Configurations
- Flange x Flange
- Flange x Weld
- Weld x Weld
Flanges available in the following formats;
- ANSI 16.5, 16.47, MSS-SP-44
- Techlok
- SPO
- Graylok
- API6A
- FF (Flat Face), RF (Raised Face), RTJ (Ring
Type Joint)
Long form / Short Form
- Long form – Venturi meters with 7° exit angle. Longer lay length with lower non-recoverable pressure loss.
- Short form – Venturi meters with 15° exit angle. Shorter lay length with non- recoverable pressure loss slightly higher than Long form.
- Truncated form – Allows a 33% reduction in the outlet cone length. Non-recoverable pressure loss affected.
Pressure Tap Options
- NPT taps
- Flanged taps
- Piezo Annular rings
- Valved taps
Benefits
- High Accuracy, precision machined orifice fitting.
- Minimal maintenance required.
- Available in sizes from 2” to 60”
- Manufactured to suit application
- Used to measure a wide range or mediums
- Short , Long and Truncated forms available
- Use of modern seals and simplest designs
- No moving parts = no maintenance
Options
- Exotic Materials for demanding service – Duplex, Inconel.
- High Pressure solutions (10,000PSI)
- Wide Temperature ranges.
- Long form or Short form
- Meter Runs and instrumentation
- Bespoke design service
- Standard tapping’s , valves or ‘Piezo’ annular
rings. - Pressure loss monitoring
Design Codes
- ASME B31.8 Gas Transmission and Distribution Piping
- NACE MR-01-75
- ASME B31.1 Power Piping
- ASME B31.3 Liquid Petroleum Transportation
Piping Systems - PED 97/23/EC – Pressure Equipment Directive
Measurement Standards
- ISO 5167-4:2003
- ASME MFC-3M
Maximising the Venturi Meter
To ensure absolute metering accuracy, it is recommended that meter tubes are purchased and manufactured to complement the venturi meter. This ensures concentricity between the pipe and the fitting, and eliminates uncertainties associated with misalignment.
LEADING can supply the following items for a complete metering solution;
- Venturi with Meter Tube including process connections
- DP transmitters and Process Transmitters
- Flow Computer and Enclosure